Two simultaneous leaks isolation in a pipeline by transient responses
Conference Paper
-
- Overview
-
- Research
-
- Identity
-
- Additional Document Info
-
- View All
-
Overview
abstract
-
This paper presents a procedure to isolate two simultaneous leaks in a pipeline using the parameter estimation framework with a reduction in the research interval of the four unknown parameters when only pressure and flow rate are measured at the extremes of the line. Considering the steady state parameter Zeq which characterizes the subset of two indistinguishable leaks, a family of dynamic models with constraints is obtained. This family, called F, allows to reformulate in a simple way the leaks identification task in which diverse off-line optimization algorithms can he used to solve it. The formulation of the optimization task with constraints is the main contribution of this work. The advantages of the family F in term of the search interval reduction are discussed using the parameters of a water pilot pipeline of 135m long in which the L2 norm of the upstream flow error is minimized using real data. © 2005 IEEE.
publication date
published in
Research
keywords
-
Flow rate; Leaks isolation; Transient responses; Algorithms; Constraint theory; Flow control; Mathematical models; Optimization; Parameter estimation; Water pipelines; Leak detection
Identity
Digital Object Identifier (DOI)
Additional Document Info
start page
end page
volume