abstract
-
This paper addresses the calculation of the induced voltage in the stator winding of a permanent magnet synchronous motor under armature fault conditions. The generalized harmonic analysis is used to model the motor winding and the magnetic field in the air gap produced by the permanent magnet. Simulation results of unbalanced induced voltage are illustrated and analyzed in detail. © 2014 IEEE.
publication date
published in
Research
keywords
-
Análisis armónico generalizado; fallas en devanados de armadura; motor de imán permanente Electric motors; Magnetic devices; Magnets; Permanent magnets; Synchronous motors; Winding; fallas en devanados de armadura; Fault conditions; Generalized harmonic analysis; Induced voltages; Motor windings; Permanent magnet motor; Permanent Magnet Synchronous Motor; Stator winding; Machine windings