Measurement of levofloxacin in human plasma samples for a reliable and accessible drug monitoring
Article
Overview
Research
Identity
Additional Document Info
View All
Overview
abstract
Objectives Levofloxacin monitoring is recommended to obtain clinical cure and low incidence of antimicrobial resistance. During the monitoring procedure, levofloxacin should be measured in plasma samples and several assays are reported for this purpose. However, those methods do not have all of the characteristics for an accessible and reliable drug monitoring. For this reason, we develop a method that has all of the essential characteristics for levofloxacin monitoring. Design and methods The procedure of validation was done in terms of Food and Drug Administration guidelines. Subsequently, our assay was applied in plasma samples obtained from healthy volunteers with a single oral administration of levofloxacin as well as patients with respiratory diseases under levofloxacin therapy. Results Levofloxacin was extracted from samples using only two precipitation steps. Our assay had a rapid run time (5 min), adequate sensitivity (0.05 μg/ml of lower limit of quantification), and acceptable parameters of validation. Moreover, compound identities were supported using three dimensional spectra and purities were confirmed employing similarity factors (values > 900). Variable concentrations of levofloxacin in samples were observed during the application. Conclusions Levofloxacin is successfully quantified using our method that shows reliable results, appropriate range, rapid analyses, and cost-effective measurements under a simple and easy technique while all prior methods did not have it all together. Consequently, our method is a valuable tool for routine drug monitoring. Moreover, a complete evaluation of specificity was done for levofloxacin in plasma samples for the first time. Meanwhile, the application data supported the necessity of levofloxacin monitoring. © 2016 The Canadian Society of Clinical Chemists
publication date
funding provided via
published in
Research
keywords
Diode array technology; Drug monitoring; Levofloxacin; Liquid chromatography; Validation levofloxacin; antiinfective agent; levofloxacin; accuracy; adult; Article; calibration; drug blood level; drug monitoring; drug purity; food and drug administration; human; normal human; practice guideline; priority journal; reliability; respiratory tract disease; sensitivity analysis; single drug dose; validation study; blood; drug monitoring; reproducibility; standards; Anti-Bacterial Agents; Drug Monitoring; Humans; Levofloxacin; Reproducibility of Results
Identity
Digital Object Identifier (DOI)
PubMed ID
Additional Document Info
start page
end page
volume
issue