Antenna-coupled microbolometers on a silicon-nitride membrane
Article
-
- Overview
-
- Research
-
- Identity
-
- Additional Document Info
-
- View All
-
Overview
abstract
-
Square-spiral antenna-coupled microbolometers made of gold and chrome are fabricated on a silicon-nitride membrane. The membrane gives mechanical stability and thermal isolation to the detectors so that they can be used as picture elements in commercial infrared-imaging systems. The fabricated devices are measured under room pressure and under vacuum, giving D* values of 3 × 10 6 cm√Hz/W and 1.7 × 10 7 cm√Hz/W, respectively. By using vanadium-oxide, values well above 1 × 10 8 cm√Hz/W for D* can be obtained. Variations to the fabrication process that will allow the use of vanadium oxide are suggested. © 2005 Wiley Periodicals, Inc.
publication date
published in
Research
keywords
-
Antenna-coupled detectors; Microbolometers; Responsivity; Silicon nitride membrane; Thermal impedance Antenna-coupled detectors; Microbolometers; Responsivity; Silicon nitride membranes; Bolometers; Gold; Imaging systems; Silicon nitride; Vanadium compounds; Membranes
Identity
Digital Object Identifier (DOI)
Additional Document Info
start page
end page
volume
issue